Not yet available: no safety data sheet for Terra Prime or Terra Fog has been supplied to us. Ask for it before any application; we do not substitute another product's sheet.

Test results

Holt Engineering tested soil untreated and treated with Top-Seal White. These are reported results on specific samples, published with their sources.

Unconfined compressive strength (PSI)
Sample Scale PSI
Untreated soil 132
Top-Seal White, medium strength 1,400
Top-Seal White, high strength 2,200
Source: Holt Engineering compressive strength testing, as reported in the product line's engineering presentation.
Permeability coefficient
Sample Coefficient
EPA reference standard 1.00E-07
Top-Seal White, medium strength 3.20E-08
Top-Seal White, high strength 1.00E-09
A lower coefficient means the soil lets less water through. The EPA reference standard is shown for comparison. Source: Holt Engineering permeability testing, Austin, Texas, January 8 2018, as reported in the landfill composite liner drawing.

Need a document for a specific application?

Tell us the application and we will point you to the documents that belong to it, and the rate that goes with that use rather than a general figure.